Range Selector
Purpose
This is a more sophisticated logic device than the simple Boolean devices. The simple explanation is that if the input is between the minimum and the maximum, the output is on. There is an additional output that is either 0% or whatever percentage that is set in the Trigger level, depending on whether the Full Output is on (Trigger Level %) or off (0%). This device is typically used with Control Grouped input and outputs
Controls
Input
Input to the Range Selector.
Range Minimum
The minimum value that you want the input to be to have the output to be on. This is accurate to 0.1 percent.
Range Maximum
The maximum value that you want the input to be to have the output to be on. This is accurate to 0.1 percent.
Trigger Level
Optionally, you can enter a percentage here that will be copied to the Output Level whenever the Full Output is on. This is useful for those instances where the device you are triggering shouldn't just have 100% or 0%, such as a level or router.
Output Level
Either 0% if the input is out of the range specified in the Minimum and Maximum or the same value as the Trigger Level if the input falls between the Minimum and Maximum.
Full Output