CV Inputs and Outputs

CAB 8i CobraNet Input BoB and CAB 8o CobraNet Output BoB

Both the CAB 8i and CAB 8o have eight control voltage (CV) inputs and outputs, plus 8 relay contact points with normally closed, normally open, and common contacts brought out to the rear panel. The CV inputs have a 0 to 10V range, while the outputs are 5V digital TTL outputs. The relay contact closure points come directly from the remote controlled relays, and are of a SPDT configuration.

Analog BoB's

The eight control outputs appear on a separate Phoenix connector on the back of the breakout box. They provide logic outputs from the system. The output voltage is TTL format. Outputs are capable of sourcing 6ma and sinking 20ma while maintaining valid TTL levels.

Example Connections

 

10K Pot

Connect wiper to desired control input pin

Connect one side of resistor to any control voltage pin

Connect other side of resistor to any ground pin

 

Switch Closure

Connect one side of switch to desired control input pin

Connect other side of switch to any control voltage pin

 

Variable Voltage Source ( 10 Volts MAX )

Connect one side of source to desired control input pin

Connect other side of source to any ground pin

The eight control outputs appear on a separate Phoenix connector on the back of the breakout box. They provide logic outputs from the system. The output voltage is TTL format. Outputs are capable of sourcing 6ma and sinking 20ma while maintaining valid TTL levels. These outputs can be used to control devices as follows:

For in-depth examples, see the MediaMatrix PDF Library web page for white papers on MediaMatrix external control.

Related Topics

MM88xx BoB Hardware

MM8802 BoB Hardware
Control Input Calibration

CAB 8i

CAB 8o