XControl® 4S

The Peavey MediaMatrix® XControl 4S is a programmable, flush-mount control panel designed for the X-Frame™ 88 and MM™ Series audio processing products. Designed for easy implementation, the 4S provides powerful, yet intuitive access to multiple controls within MWare™ and XWare™ software applications. Fully programmable, the 4S can be configured for a large variety of uses. A simple music select panel, control for message playback or scene recall for use with MediaMatrix' powerful preset functionality are just a few of the possibilities. Changing the configuration is easy and installation couldn't be simpler, thanks to the XControl RS-485 network and flexible power options. The 4S makes user control for MediaMatrix systems intuitive and flexible.

Download owner's manual (PDF - 3.99 MB)
Download Spec Sheet (PDF - 280 KB)

FEATURES:
. 1-gang NEMA mount
. 4 assignable soft buttons
. LED indicators indicate button function
. Programmable for trigger or switch operation
. Label space for customization

DOWNLOAD FRONT PANEL DRAWING
XControl 4S.dwg (AutoCAD 2000)
XControl 4S.dxf (AutoCAD R14)

SPECIFICATIONS
Mechanical:
NEMA 1-gang finish plate, requires 2.25" clearance depth minimum. Mount in metal box coupled to EMT conduit. NOTE: Take care to ensure that conduit coupling hardware, wire or other terminating devices do not obstruct the installation of the 4S's circuit assembly.

Power requirements & connection:
12-24V DC or 9-16V AC, 15 mA per panel. Screw terminal connections, #6 spade lug (included) required.

Data Connection:
RS-485 two-wire, half duplex. 32 panel support for MWare, 8 panel support for XWare. Screw terminal connections, shipped with #6 spade lug. Terminating resistors (120 ohms) supplied for EOL connections.

Firmware:
Programmable flash memory.

Finish:
Grey powder-coat on 18 gauge CRS.

Net Weight:
Approximately 1 lb. (0.45 kg)